Item Comparison: FRSR70, ECSR70

Item

FRSR70 - 70A 600V TD Class RK5 Dual Elem Fuse-Fusetron - Eaton Bussmann Series

FRSR70
70A 600V TD Class RK5 Dual Elem Fuse-Fusetron

$105.43 Each

$527.15 (5 Each)

QTY:
Each
Add
ECSR70 - 70A 600V Class RK5 Time Delay CL Fuse - Edison

ECSR70
70A 600V Class RK5 Time Delay CL Fuse

$78.50 Each

$392.50 (5 Each)

QTY:
Each
Add
Nacogdoches 0 0
All Stores 33 95
Vendor Eaton Bussmann Series Edison
Catalog Number FRSR70 ECSR70
Manufacturer Number FRS-R-70 ECSR70
Category Distribution Fuses - Dual Element Distribution Fuses - Dual Element
Classification Fuses & Fuse Accessories Fuses & Fuse Accessories
UNSPSC 39121606 - Cartridge fuses 39121604 - Time delay fuses
UPC/EAN/GTIN 00051712508407 00782634508403
Weight per package 0.4 (lbs/each) 0.38 (lbs/each)
Description FRSR70 70A 600V TD Class RK5 Dual Elem Fuse-Fusetron
Time Delay Fusetron Fuse, RK5 Class Fuse, Dual Element Fuse, 10 S @ 500% Response Time, Blade End X Blade End Connection, 70 A, 600 V Ac;300 V DC, Blade Terminal, 1.11 In Diameter, 7.88 In Overall Length, 0.4 LB
ECSR70 70A 600V Class RK5 Time Delay CL Fuse
Time Delay Power Fuse, RK5 Class Fuse, Blade Fuse, 10 S @ 500% Response Time, Blade End X Blade End Connection, 70 A, 600 V Ac, Blade Terminal, 1.11 In Diameter, 7.88 In Overall Length, 0.54 LB
Minimum Order QTY 1 Unit 1 Unit
Unit/Foot $105.43 (Each) $78.50 (Each)
Carton/Reel $105.43 (1 Each) $78.50 (1 Each)
Standard Packaging/Reel $527.15 (5 Each) $392.50 (5 Each)
amperage rating 70 A -
Characteristics - 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT
connection Blade End X Blade End -
Current Rating 70 A 70 A
interrupt rating 200 kAIC (RMS Symmetrical):20 kAIC (DC) 200 kAIC
Interrupting Rating - 200 KILOAMPERE (SYMMETRICAL)
Terminal Type Blade Blade
Voltage Rating 600 V ac;300 V dc 600 V ac
Diameter 1.11 in 1.11 in
Length - 7.88 INCH
Overall Length 7.88 in 7.88 in
Size 1.11 In Diameter X 7.88 In Length -
Additional Information - Application Branch and Feeder Circuit, AC Drive, Loadcenter, Panel Board and Switch Board, Non-Inductive Load, General Purpose, Lighting and Heating
Commodity Description - DUAL ELEMENT FUSES
Description 70A 600V TD CLASS RK5 DUAL ELEM FUSE-FUSETRON 70A 600V CLASS RK5 TIME DELAY CL FUSE
extra long description BUSS FRS-R-70 FUSETRON DUAL ELEMENT CLASS RK5 TYPE; 7.88 INCH; UL, CSA C22.2, CE APPROVAL; 600 VAC VOLTAGE RATING; 1.11 INCH DIAMETER; 200 KILOAMPERE (SYMMETRICAL) INTERRUPTING RATING; 70 AMPERE CURRENT RATING; BLADE TERMINAL TYPE; 10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT CHARACTERISTICS; APPLICATION BRANCH AND FEEDER CIRCUIT, AC DRIVE, LOADCENTER, PANEL BOARD AND SWITCH BOARD, NON-INDUCTIVE LOAD, GENERAL PURPOSE, LIGHTING AND HEATING; ECSR MODEL
Features Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses. Time-delay – 10 seconds (minimum) at 500% of rated current. These fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short-circuit current does not exceed 200,000 RMS symmetrical amps. These “dual-element, time-delay” fuses have minimum industry standard time-delay of 10 seconds at 5 times the fuse rating (8 sec. minimum for 250V, 30A and less). The time-delay characteristics of these fuses typically allows them to be s
Long Description Time Delay Fusetron Fuse, RK5 Class Fuse, Dual Element Fuse, 10 s @ 500% Response Time, Blade End x Blade End Connection, 70 A, 600 V ac;300 V dc, Blade Terminal, 1.11 in Diameter, 7.88 in Overall Length, 0.4 lb Time Delay Power Fuse, RK5 Class Fuse, Blade Fuse, 10 s @ 500% Response Time, Blade End x Blade End Connection, 70 A, 600 V ac, Blade Terminal, 1.11 in Diameter, 7.88 in Overall Length, 0.54 lb
Product Type Fusetron Dual Element Fuse Class RK5 Time Delay Power Fuse
Short Description Fusetron Fuse, 70 A, 600 VAC/300 V dc, Time Delay, RK5 Class Power Fuse, 70 A, 600 VAC/300 V dc, Time Delay, RK5 Class, ID
Special Features Renewable -
class Class RK5 -
Connection Type Blade End x Blade End Blade End x Blade End
dimensions 5.0000 IN X 0.8100 IN X 0.8100 IN -
element Dual -
Fuse Class RK5 Class RK5 Class
Fuse Type Dual Element Blade
media Yes -
package quantity 1 ct 1 ct
Response Time 10 s @ 500% 10 s @ 500%
Standards Met UL Listed;STD. 248-12;Class RK5;Guide JDDZ, File E4273;CSA Certified;C22.2 No. 248.12, Class 1422-02, File 53787;CE Certified UL Listed;STD. 248-12;Class RK5;Guide JDDZ, File E162363 CSA Certified;HRCI-R C22.2 No. 248.12, Class 1422-02, File 53787;CE Certified
Made in USA yes yes
Brand Eaton EDISON
Manufacturers Part Number FRS-R-70 ECSR70
Model - ECSR
Category Description Fuses & Fuse Accessories Fuses & Fuse Accessories
Type FUSE CLASS RK5
Weight 0.4 lb 0.54 lb;0.24 kg
Application Combination Starters;Motor Control Centers;Machinery Disconnects;Power Panelboards AC Power Distribution System mains, Feeders, and Branch Circuit;Protection of Motor and Motor Branch Circuit;Protection of Transformer and inductive Load;All General Purpose Application including Lighting, Heating and Other Non-inductive Load
Approval - UL, CSA C22.2, CE
standard CE Marked -
 
QTY:
Each
Add
QTY:
Each
Add

Begin Live Chat